Neko  0.8.1
A portable framework for high-order spectral element flow simulations
fluid_fctry.f90
Go to the documentation of this file.
1 ! Copyright (c) 2021, The Neko Authors
2 ! All rights reserved.
3 !
4 ! Redistribution and use in source and binary forms, with or without
5 ! modification, are permitted provided that the following conditions
6 ! are met:
7 !
8 ! * Redistributions of source code must retain the above copyright
9 ! notice, this list of conditions and the following disclaimer.
10 !
11 ! * Redistributions in binary form must reproduce the above
12 ! copyright notice, this list of conditions and the following
13 ! disclaimer in the documentation and/or other materials provided
14 ! with the distribution.
15 !
16 ! * Neither the name of the authors nor the names of its
17 ! contributors may be used to endorse or promote products derived
18 ! from this software without specific prior written permission.
19 !
20 ! THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
21 ! "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
22 ! LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
23 ! FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
24 ! COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
25 ! INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
26 ! BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
27 ! LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
28 ! CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
29 ! LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
30 ! ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
31 ! POSSIBILITY OF SUCH DAMAGE.
32 !
35  use fluid_scheme, only : fluid_scheme_t
36 ! use fluid_plan1, only : fluid_plan1_t
37  use fluid_pnpn, only : fluid_pnpn_t
38  use utils, only : neko_error
39  use neko_config
40  implicit none
41 
42 contains
43 
45  subroutine fluid_scheme_factory(fluid, fluid_scheme)
46  class(fluid_scheme_t), intent(inout), allocatable :: fluid
47  character(len=*) :: fluid_scheme
48 
49  if (trim(fluid_scheme) .eq. 'plan1') then
50 ! allocate(fluid_plan1_t::fluid)
51  else if (trim(fluid_scheme) .eq. 'pnpn') then
52  allocate(fluid_pnpn_t::fluid)
53  else
54  call neko_error('Invalid fluid scheme')
55  end if
56 
57  end subroutine fluid_scheme_factory
58 
59 end module fluid_fctry
Factory for all fluid schemes.
Definition: fluid_fctry.f90:34
subroutine fluid_scheme_factory(fluid, fluid_scheme)
Initialise a fluid scheme.
Definition: fluid_fctry.f90:46
Modular version of the Classic Nek5000 Pn/Pn formulation for fluids.
Definition: fluid_pnpn.f90:34
Fluid formulations.
Build configurations.
Definition: neko_config.f90:34
Utilities.
Definition: utils.f90:35
Base type of all fluid formulations.